6kA Mini Circuit Breaker
10KA Mini Circuit Breaker
6KA Series Residual Current Circuit Breaker
10KA Series Residual Current Circuit Breaker
STBL1-40 Residual Current Operated Circuit Breaker
STBL1-63 Residual Current Operated Circuit Breaker
Residual Current Operated Circuit Breaker
STI1 Isolating Switch
STB1-DPN Miniature Circuit Breaker
STB1-100H Miniature Circuit Breaker
Circuit Breaker Accessories
Indicating Light
Door Bell
Transformer
STTM-16 time switch
STTM-E8 time switch
time switch TM160
time switch STM161H
STTM time switch STM15
Measuring Device
STDS-1 Series Single-phase DIN-Rail electronic energy meter
Fuse Holder and Links
Modular Contactor
Surge Protective Device
Surge Protective Device
Insulated Busbars
Consumer Units
Metal Distribution Board
Fuse Holder and Links
Metal Distribution Board
Magnetic Relay
Extention Terminal
Modular Socket
IP Rated & Metal Enclosures
6kA Mini Circuit Breaker
SPECIFICATIONS | Tripping Curve | Rated current (A) | Pole | Voltage (V) | Breaking capacity (A) | Standard |
6A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 6000 | IEC60898 |
10A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 6000 | IEC60898 |
16A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 6000 | IEC60898 |
20A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 6000 | IEC60898 |
25A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 6000 | IEC60898 |
32A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 6000 | IEC60898 |
40A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 6000 | IEC60898 |
50A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240 | 4500 | IEC60898 |
63A | B.C.D | 1 to 63 | 1,2, 3, 4 | 400/415 | 4500 | IEC60898 |
STB1-63 series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short-circuit in the system. The product novel in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly and its installation uses with guide, its case and items are adopted with high fire-resistant and shockproof plastic. The product, with long life, is mainly used in AC 50/60Hz single-pole 240V or two, three, four-pole 415V circuit for overload and short-circuit protection as well as for unfrequent on-and-off switching electric equipment and lighting circuit in normal case. This product conform with GB10963, IEC60898.
10KA Mini Circuit Breaker
SPECIFICATIONS | Tripping Curve | Rated current (A) | Pole | Voltage (V) | Breaking capacity (A) | Standard |
6A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 10000 | IEC60898 |
10A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 10000 | IEC60898 |
16A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 10000 | IEC60898 |
20A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 10000 | IEC60898 |
25A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 10000 | IEC60898 |
32A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 10000 | IEC60898 |
40A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 10000 | IEC60898 |
50A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 10000 | IEC60898 |
63A | B.C.D | 1 to 63 | 1,2, 3, 4 | 240/240, 400/415 | 10000 | IEC60898 |
STB1-63 series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short-circuit in the system. The product novel in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly and its installation uses with guide, its case and items are adopted with high fire-resistant and shockproof plastic. The product, with long life, is mainly used in AC 50/60Hz single-pole 240V or two, three, four-pole 415V circuit for overload and short-circuit protection as well as for unfrequent on-and-off switching electric equipment and lighting circuit in normal case. This product conform with GB10963, IEC60898.
6KA Series Residual Current Circuit Breaker
Catalogue Number | Rated Current (A) | Number of Pole | Rating | Type | Un(V) | IΔc(A) |
STR1-63/2P | 16,20,25,32, 40,50,63 | 2P | 10,30, 100,300 | AC,A | 230VAC | 6000 |
STR1-63/4P | 16,20,25,32, 40,50,63 | 4P | 10,30, 100,300 | AC,A | 400VAC | 6000 |
The RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault circuit immediately on the occasion of shock hazard of earth leakage of trunk line. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. The RCCB is mainly suitable for useing in varieties of plants and enterprises, buildings constructions. It can be used in circuits up to 1 phase 230V and 3 phase 400V 50/60Hz. RCCB is not suitable for use on DC pulse system.
10KA Series Residual Current Circuit Breaker
Catalogue Number | Rated Current (A) | Number of Pole | Rating | Type | Un(V) | IΔc(A) |
STR1-63H/2P | 16,20,25,32, 40,50,63,80,100 | 2P | 10,30, 100,300 | AC,A | 230VAC | 10000 |
STR1-63H/4P | 16,20,25,32, 40,50,63,80,100 | 4P | 10,30, 100,300 | AC,A | 400VAC | 10000 |
The RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault circuit immediately on the occasion of shock hazard of earth leakage of trunk line. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. The RCCB is mainly suitable for useing in varieties of plants and enterprises, buildings constructions. It can be used in circuits up to 1 phase 230V and 3 phase 400V 50/60Hz. RCCB is not suitable for use on DC pulse system.
STBL1-40 Residual Current Operated Circuit Breaker
Catalogue Number | Rated Current (A) | Number of Pole | Rating | Type | Un(V) | IΔc(A) |
STBL1-40 | 6,10,16,20, 25,32,40 | 1P+N | 10,30, 100,300 | AC,A | 230VAC | 6000 |
• Stylish modern profile, matches all other SETEN devices • Double pole module• Positive contact status indicator • Available from 6 to 40A rating • Available in B,C type • Lockable dolly switch
STBL1-63 Residual Current Operated Circuit Breaker
Catalogue Number | Rated Current (A) | Number of Pole | Rating | Type | Un(V) | IΔc(A) |
STBL1-63 | 6,10,16,20, 25,32,40,63 | 1P+N,2P,3P, 3P+N,4P | 30,100,300 | AC,A | 240V/415V | 6000, 10000 |
STBL1-63 RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage 240V/415V. When an electric shock or the residual current of the circuit exceeds the threshold value, the RCBO can cut off the power within the time of 0.ls to protect the personal safety and prevent the equipment from the fault result by the residual current. Combined with MCB RCBO, it can also protect the circuit against overload and short circuit.It conforms to IEC61009 standard.
Residual Current Operated Circuit Breaker
Catalogue Number | Rated Current (A) | Number of Pole | Rating | Type | Un(V) | IΔc(A) |
STNLE-32 | 6,10,16,20, 25,32 | 1P+N | 10,30, 100,300 | AC,A | 230VAC | 4500 |
STBR1-40 | 6,10,16,20, 25,32 | 1P+N | 10,30, 100,300 | AC,A | 230VAC | 6000, 10000 |
• Stylish modern profile, matches all other SETEN devices • Simple pole module• Positive contact status indicator • Available from 6 to 40A rating • Available in B,C type • Lockable dolly switch
STI1 Isolating Switch
Catalogue Number | Rated current (A) | Number of Pole | Un(V) | Utilization category |
STI1 | 16,20,25,32,40,50,63,80,100,125 | 1P,2P,3P,4P | 230/400VAC | AC-22A |
STI1 main switch is designed to accept cable-in/cable-out connections. It may be used as an isolating switch. The switch disconnected is capable of switching both resistive and inductive loads.The product conforms to IEC60947-3.
STB1-DPN Miniature Circuit Breaker
Catalogue Number | Tripping Curve | Rated current (A) | Pole | Voltage (V) | Breaking capacity (A) | Standard |
STB1-DPN | B.C.D | 1 to 40 | 1P+N | 230 | 4500 | IEC60898 |
STB1-100H Miniature Circuit Breaker
Catalogue Number | Tripping Curve | Rated current (A) | Pole | Voltage (V) | Breaking capacity (A) | Standard |
STB1-100H | B.C.D | 1 to 125 | 1P+N | 230/400VAC | 10000 | IEC60947-2 |
STB1-100H mini circuit breaker is used in AC 50Hz or 60Hz, single phase 230/240V, three phase 400/415V to protect the circuit against overload and short circuit. It can be used in lighting and motor circui t. It can also be used for infre quent switch on and off of the lighting and equipment under normal condition. The breaking capacity is 10kA according to IEC60947-2.
Circuit Breaker Accessories
Catalogue Number | Electric endurance | Rated insulation voltage | Mechanicalendurance | Voltage (V) | Dielectric strength | Standard |
STBA-OF | 30000 | Ui 500V | 40000 | 230VAC | 2000V/1min | IEC 60947-5-1 |
STBA-SD | 30000 | Ui 500V | 40000 | 230VAC | 2000V/1min | IEC 60947-5-1 |
STBA-MX | 30000 | Ui 500V | 40000 | 230VAC | 2000V/1min | IEC 60947-5-1 |
STBA-MN | 30000 | Ui 500V | 40000 | 230VAC | 2000V/1min | IEC 60947-5-1 |
OF Auxiliary contactContact capacity:AC:Un=400V In=3AUn=230V In=6ADC:Un=125V In=1AUn=48V In=2AUn=24V In=6ADielectric strength:2000V/1minMounted on the left side of the MCB STB1-63H.
SD Alarming contactSend out signals when the circuit breaker pail to trips.Mechanical indicator on the front panel, which can indicate failure trip.Screw-type thread pressed terminal,can connect with 1 or 2 conductiong wire of 2.5 mm2 max.cross sectional area.Obvious marks upon terminal.Mounted on the left side of the MCB STB1-63H.indication"ON","OFF" status of combined MCB.
MX Shunt trip Rated insulating voltage(Ui):500VRated power voltage(Us):AC 400,230,125VOperate voltage range:70~100% UsContact capacity: AC:3A/400V AC:6A/230VAC:9A/125V Dielectric strength:2000V/1minMounting on the right side of MCB/RCBO, used to trip the combined MCB/RCBO by remotecontrolling device.
MN Over-voltage/undervoltage trip Rated voltage(Ue):AC 230VRated insulating voltage(Ui):500VOver-voltage tripping range:280V±5%Under-voltage tripping range:170V±5%Mounted on the right side of circuit breaker, actuate the combined device to trip in case of undervoltageor over-voltage, effectively prevent the device from closing operation under abnormalpower voltage condition.
Indicating Light
Catalogue Number | Color | Life | Voltage (V) | Altitude | Mounting | Standard |
ST1SL | Red, green, yellow, orange,blue, white | incandescence lamp ≥1000h neon lamp≥2000h LED≥30000h | 230VAC 50/60Hz | not exceed 2000m | On 35mm DIN rail | IEC 60947-5-1 |
The Modular Signal is applicable to circuit with rated voltage 230Vand frequency 50/60Hz for visual indication and signaling.
Door Bell
Catalogue Number | Installation class | Pollution grade | Working condition | Electric ratings | Mounting | Standard |
ST1SO | II & III | ll | Short-time | 8V,12V, 24V,110V, 230V, 50/60Hz | On 35mm DIN rail | IEC61558-1 |
Application scopeST1SO be applicable to circuit with rated voltage 230V, rated frequency 50Hz/60Hz and rated current not exceeding 63A, providing the function of sound warning and prompting.
Transformer
Catalogue Number | Transformer out power capacity | Non-load current Io(mA) | Non-load wastage Po(w) | Output voltage | Input voltage | Standard |
ST1TF | 3.8VA, 8VA | 36±6 | 1.12 | 4V, 6V, 8V, 12V,16V,24V | 230/240V 50/60Hz | IEC61558-1 |
Application scopeBell transformer is applicable to circuit of AC 50Hz, operating voltage up to 250V. With output power capacity 3.8VA and 8VA, the product functions as ideal and safe power supply for household door bell.
STTM-16 time switch
Type:electromechanical type with time delayTime setting range: 7 minutesMin.setting interval: 30 secondsToggle switch: manual/automaticControlled lighting load:Incandescent lamp: 2300WHalogen lamp: 2300WFluorescent lamp:Uncompensated 2300wCompensated in series: 2300wCompensated in parallel: 1300wSwitching: reset after 30s
STTM-E8 time switch
Type: electronic time delayTime setting range: 20 minutesMin.setting interval: 5 minutesSlide switch: manual/automaticControlled lighting load:Incandescent lamp: 2300WHalogen lamp: 2300WFluorescent lamp load with electronic ballast: 800WSwitching: immediate reset
time switch TM160
STTM-160 Synchronous time switchDrive: synchronous motorFrequency: 50/60HzWithout batterySTTM-180 Quartz time switch with power reserveDrive: quartz-controlled motorFrequency: 50/60HzAccuracy: within±1s per day at 20oCReserve: 70 hoursTechnical DateConsumption: 2.5VAContact: 1NOContact capacity:16A/250V AC (COSφ=1)4A/250V AC (COSφ=0.6)Electrical endurance: 105 cyclesMechanical endurance: 107 cycles24 hours 96 segmentsmin.programmable interval: 15minutesAmbient temperature: -10oC~+50oC
time switch STM161H
STM161H Synchronous time switchDrive: synchronous motorFrequency: 50/60HzSTT2-181h Quartz time switch with power reserveDrive:quartz-controlled motorFrequency: 50/60HzAccuracy: within±1s per day at 20oCReserve: 150 hoursTechnical DateConsumption: 2.5VAContact capacity: 16A/250V ACcyclesElectrical endurance: 105 cyclesMechanical endurance: 107 cycles24 hours program 48 segmentsmin.programmable interval: 30minutesAmbient temperature: -20oC~+50oC
STTM time switch STM15
STM15 Type: electronic with LCD displayRated voltage: 230V ACRated frequency: 50/60HzContact: 1NO+1NCConsumption: maximun 4VAContact capacity:16A/250V AC (COSφ=1)2.5A/250V AC (COSφ=0.6)Incandescent lamp: 1000WElectrical endurance: 105 cyclesMechanical endurance: 107 cyclesTime basis: quartz24 hours + week programWorking precision: ≤2 sec/day(25oC)min.programmable interval: 1minutesPower reserve:min. 15 daysAmbient temperature: -10oC~+40oCHumidity: 35-85%RH
Measuring Device
Standard
Rated insulation
Temperature range
Terminal capacity(Max)
Type of terminal
Module width
Confirming to EN / IEC60051-1-2
600V AC
-25oC~+40oC
6mm2
Pin type
36mm
STPM-45A Ammeter
Rated Frequency: 50Hz
Power Consumption: 1.5VA
Accuracy: Class 1.5
Temperature Range: -25oC~+40oC
Insulation Voltage: 600V
STPM-45V Voltmeter
Rated Frequency: 50Hz
Power Consumption: 3.5VA
Range: 0-600V.0-300V
Accuracy: Class 2.5
Temperature Range: -25oC~+40oC
Insulation Voltage: 600V
STPM-D45A Ammeter
Display: 3 1/2 Digitals
Accuracy: 0.5%
Standards: EN / IEC60051-1-2
Rated current: 0-10A AC,0-5A AC
Auxiliary voltage: 115/230V 50Hz
Power consumption: 1.8VA
Rated frenquency: 50Hz
Insulation voltage: 660V
Test voltage at 50Hz 1 min: 2000V
Terminal capacity(Max): 4mm2
STPM-D45V Voltmeter
Display: 3 1/2 Digitals
Accuracy: 0.5%
Standards: EN / IEC60051-1-2
Rated voltage: 600VAC
Auxiliary voltage: 115/230V 50Hz
Power consumption: 1.8VA
Rated frenquency: 50Hz
Insulation voltage: 660V
Test voltage at 50Hz 1 min: 2000V
Terminal capacity(Max): 4mm2
STDS-1 Series Single-phase DIN-Rail electronic energy meter
One module
Model: LCD 10100L
Counter 10100M
Rated Voltage: 110V,220V,230V,240V
Rated Current: 5(32)A,5(40)A,5(45)A,5(50)A
Accuracy Class: 1.0
Frequency: 50/60Hz
Impulse Constant: 1000imp/kWh,2000imp/kWh
Display: LCD,Counter
Power Consumption: ≤8VA,≤0.4W
Start Current: 0.4%Ib
Connection Mode: Direct type
Standard: IEC62052-11,IEC62053-21
DIN EN 50022,DIN43880
Two module
Model: LCD 20100L
Counter 20100M
Rated Voltage: 110V,220V,230V,240V
Rated Current: 5(32)A,5(40)A,5(50)A,5(80)A
Accuracy Class: 1.0, 2.0
Frequency: 50/60Hz
Impulse Constant: 1000imp/kWh,2000imp/kWh
Display: LCD,Counter
Power Consumption: ≤8VA,≤0.4W
Start Current: 0.4%Ib
Connection Mode: Direct type
Standard: IEC62052-11,IEC62053-21
DIN EN 50022,DIN43880
Four module
Model: LCD 40100L direct type
LCD 40200L CT type
Counter 40100M direct type
Counter 40200M CT type
Rated Voltage: 110V,220V,230V,240V
Rated Current: 1.5(6)A,5(20)A,5(30)A,10(40)A,15(60)A,20(80)A,10(100)A
Accuracy Class: 1.0
Frequency: 50/60Hz
Impulse Constant: 800imp/kWh,1600imp/kWh,12000imp/kWh
Display: LCD,Counter
Power Consumption: ≤1W(when 220V 20A)
Start Current: 0.4%Ib
Connection Mode: Direct type, CT type
Creep: Anti-creeping
Standard: IEC62052-11,IEC62053-21
DIN EN 50022,DIN43880
Seven module
Model: LCD G0100L direct type
LCD G0200L CT type
Counter G0100M direct type
Counter G0200M CT type
Rated Voltage: 3X110/180V,3X220/380V,3X230/400V
Rated Current: 1.5(6)A,5(20)A,10(40)A,20(80)A,10(100)A
Accuracy Class: 1.0,2.0
Frequency: 50/60Hz
Impulse Constant: 800imp/kWh,1600imp/kWh,12800imp/kWh
Display Mode: LCD,Counter
Power Consumption: ≤2W,10VA
Start Current: 0.4%Ib
Connection Mode: Direct type,CT type
Creep: Its output is less than one impulse when the voltage
is 115% voltage rating,the circuit doesn't has any current.
Standard: IEC62052-11,IEC62053-21
DIN EN 50022,DIN43880
Five module
Model: LCD E020CL CT type
Rated Voltage: 3X220/380V,3X230/400V
Rated Current: 1.5(6)A
Accuracy Class: 1.0
Frequency: 50/60Hz
Impulse Constant: 12000imp/kWh
Display: LCD 6+2/7+1/8+0
Power Consumption: ≤1W≤7VA
Start Current: 0.4%Ib
Connection Mode: CT type, CT ratio
Display Digits 6+2: 5/5,10/5,20/5,25/5,40/5,50/5,60/5
7+1: 75/5,80/5,100/5,120/5,150/5,200/5,250/5,300/5,400/5,500/5,600/5
8+0: 800/5,1000/5,1200/5,1500/5,2000/5,2500/5,3000/5,4000/5,5000/5,6000/5
Standard: IEC62052-11,IEC62053-21
DIN EN 50022,DIN43880
Fuse Holder and Links
Catalogue Number | Fuse link size | Link current | Pole | Packing unit (link) |
STF-32/P+N | 8.5×31.5mm | 2A,4A,6A 10A,16A | 1P | 20 |
STF-32 | 10×38mm | 2A,4A,6A,10A 16A,20A,25A 32A | 1P,2P,3P,4P | 20 |
STF-32 |
|
Standard | Confirming to EN / IEC60947-3 EN / IEC60269 |
Electric ratings | Up to 32A 230V AC 50/60Hz |
Type | SGF-32 (Without indicator); SGF-32X (With indicator) |
Utilization category | AC-22A |
Rated insulation voltage | Ui 500V |
Rated impulse withstand voltage | 4000V |
Electric endurance | 1500 |
Mechanical endurance | 8500 |
Operating frequency | 120/h |
Protection degree | IP20 |
Modular Contactor
Catalogue Number | Rated current(A) | Number of contacts | Packing unit |
STC1 2P(16A-25A) | 16,20,25 | 1NO 1NC 1NO+1NC | 12 |
STC1 2P(32A-63A) | 32,40,63 | 1NO 1NC 1NO+1NC | 6 |
STC1 4P(16A-25A) | 16,20,25 | 4NO 4NC 2NO+2NC 3NO+1NC | 6 |
STC1 4P(32A-63A) | 32,40,63 | 4NO 4NC 2NO+2NC 3NO+1NC | 4 |
Technical data
Standard: IEC/EN 60947-4-1,IEC/EN 61095
Maxim power:
AC1 220/230VAC:20A 4.5KW(STC1-20)
AC1 220/230VAC:25A 16KW(STC1-25)
AC1 380/400VAC:63A 40KW(STC1-63)
AC3 380/400VAC:27A 15KW(STC1-63),
AC3 380/400VAC:27A4KW(STC1-25)
Main contacts terminal capacity:
1.5-10mm2(STC1-20/STC1-25)
2.5-25mm2(STC1-63)
Coil contact A1,A2 terminal capacity: 0.75-2.5mm2
Electric endurance: ≥3×104
Mechanical endurance: ≥3×105
Protection degree: IP20
Surge Protective Device
Type | Poles | Uc(V) | In(KA) | Imax(KA) | Up(KV) | Applicable grounding system |
STS1-D/1-140-5 | 1、2 | 140 | 20 | 40 | <0.8 | Under AC110V and DC |
STS1-D/1-275-5 | 1、2 | 275 | 20 | 40 | <1.2 | TN-C, IT, TN-S |
STS1-D/1-320-5 | 1、2 | 320 | 20 | 40 | <1.5 | TN-C, IT, TN-S |
STS1-D/1-385-5 | 1、2 | 385 | 20 | 40 | <1.8 | TT |
STS1-D/1-420-5 | 1、2 | 420 | 20 | 40 | <2.0 | TT |
STS1-D/2Q-385-5 | 3 | 385 | 20 | 40 | <2.0 | |
STS1-D/3N-275-5 | 3 | 275 | 20 | 40 | <1.2 | "3+1" Compage |
STS1-D/3N-320-5 | 3 | 320 | 20 | 40 | <1.5 | "3+1" Compage |
STS1-D/4-275-5 | 4 | 275 | 20 | 40 | <1.2 | TN-C, IT, TN-S |
STS1-D/4-320-5 | 4 | 320 | 20 | 40 | <1.5 | TN-C, IT, TN-S |
STS1-D/4-385-5 | 4 | 385 | 20 | 40 | <1.8 | TT |
STS1-D/4-420-5 | 4 | 420 | 20 | 40 | <2.0 | TT |
Technical data:
Standard: Confirming to IEC61643-1
Protection: Protect electric system and on-loading electrical apparatus
from thunder and instantaneous over-voltage
Ambient temperature: -5oC to +45oC
Number of poles: 1P, 2P, 3P, 4P
Electric ratings: 230/400V, AC50/60Hz
Response time: Less than 25ms
On-Off indicating window: Green normal function
Red functionless, immediate replacement required
Pollution grade: ll
Installation class: l, ll, lll
Type of terminal: Pin type
Terminal capacity: Solid wire cross-seetion is 1-6mm2
Stranded wire cross-section is 0.75-4mm2
Installation: Mounting on 35mm DIN rail
Width: 17.5mm per pole
Ground system: "TT, TN-S, TN-C-S"are applicable to the ground system of the protector
Surge Protective Device
Rated voltage (V) | 220/380 |
Continuous operating voltage (one-pole) (V) | 385~420 |
Pole no. | 2,3,4 |
8/20µ s nominal discharge current (kA) | 40,60,80,100 |
8/20µ s maximum discharge current (kA) | 80,100,120,150 |
10/350µ s impulse discharge current (kA) | 8,10,12,15, |
Electric charge quantity (As) | 2.0, 2.5, 3.75, 5.0 |
Voltage protective level (kV) | 2.0, 2.0, 2.0.5, 3.0 |
Response time (ns) | < 25 |
Suggested connecting wire size (mm 2 ) | L, N hard wire 16, PE 25 hard wire |
Suggested fuse current (A) | 63~100 |
One-pole width (mm) | 18,27,27,27, |
Installation | Electric track of 35mm |
Type demonstration | LND-B/4-420-60 |
Technical data:
Standard: Confirming to IEC61643-1
Protection: Protect electric system and on-loading electrical apparatus
from thunder and instantaneous over-voltage
Ambient temperature: -5oC to +45oC
Number of poles: 1P, 2P, 3P, 4P
Electric ratings: 230/400V, AC50/60Hz
Response time: Less than 25ms
On-Off indicating window: Green normal function
Red functionless, immediate replacement required
Pollution grade: ll
Installation class: l, ll, lll
Type of terminal: Pin type
Terminal capacity: Solid wire cross-seetion is 1-6mm2
Stranded wire cross-section is 0.75-4mm2
Installation: Mounting on 35mm DIN rail
Width: 17.5mm per pole
Ground system: "TT, TN-S, TN-C-S"are applicable to the ground system of the protector
Insulated Busbars
Catalogue Number | Inserting method | Current ratings(A) | Poles No. | Cross section(mm) | Length(mm) |
ST-BB101 | Pin type | 63/1 | 56×1 | 20 | 100 |
ST-BB102 | U type | 63/1 | 56×1 | 20 | 100 |
ST-BB201 | Pin type | 63/2 | 27×2 | 20 | 100 |
ST-BB202 | U type | 63/2 | 27×2 | 20 | 100 |
ST-BB301 | Pin type | 63/3 | 18×3 | 20 | 100 |
ST-BB302 | U type | 63/3 | 18×3 | 20 | 100 |
ST-BB401 | Pin type | 63/4 | 14×4 | 20 | 100 |
ST-BB402 | U type | 63/4 | 14×4 | 20 | 100 |
Application:
Make wiring of electrical item easy, enlarge connection area,decrease temperature rise
Characteristics:
The busbars make wiring of electrical item easy, enlarge connection area, decrease temperature rise and increase the electrical reliability of electrical items.
Current rating up to 63 A, rated voltage up to 415 V.
Consumer Units
Catalogue Number | Dual Split Load Consumer Units | Modules |
STDB1086 | 8Way Dual Split Load Board complete With 2X63A RCDs and 1X100 Amp DP Isolator | 8 |
STDB1088 | 8Way Dual Split Load Board complete With 2X80A RCDs and 1X100 Amp DP Isolator | 8 |
STDB1126 | 12Way Dual Split Load Board complete With 2X63A RCDs and 1X100 Amp DP Isolator | 12 |
STDB1128 | 12Way Dual Split Load Board complete With 2X80A RCDs and 1X100 Amp DP Isolator | 12 |
STDB1165 | 16Way Dual Split Load Board complete With 2X63A RCDs and 1X100 Amp DP Isolator | 16 |
STDB1168 | 16Way Dual Split Load Board complete With 2X80A RCDs and 1X100 Amp DP Isolator | 16 |
STDB1226 | 22Way Dual Split Load Board complete With 2X63A RCDs and 1X100 Amp DP Isolator | 22 |
STDB1228 | 22Way Dual Split Load Board complete With 2X80A RCDs and 1X100 Amp DP Isolator | 22 |
STDB1306 | 30Way Dual Split Load Board complete With 2X63A RCDs and 1X100 Amp DP Isolator | 30 |
STDB1308 | 30Way Dual Split Load Board complete With 2X80A RCDs and 1X100 Amp DP Isolator | 30 |
The SETEN range of insulated domestic consumer units have a modern style designed to match SETEN wiring devices. They support compliance with the latest 17th Edition Wiring Regulations, with flexibility designed in to provide maximum circuit combinations, and have been designed to provide the fastest and simplest installation.
Available in insulated and metal versions (metal versions have metal base and insulated cover and visor. Allow for protected and unprotected ways, with a choice of Main Switch,Split load (one RCD), Dual RCD and option for three RCDs in 30 module unit.
Metal Distribution Board
Transparent | Teakwood | Wallnut | Outgoing ways |
STDB4-T08 | STDB4-K08 | STDB4-W08 | 8 |
STDB4-T12 | STDB4-K12 | STDB4-W12 | 12 |
STDB4-T16 | STDB4-K16 | STDB4-W16 | 16 |
Technical Data
In compliance with standards: IEC 60439-3 and BS EN 600439-3, Galavanized 1.2mm steel sheet, High quality epoxy powder surface coating, Suitable for standard MCB, Split chassis configurations for RCD, made for special request, Besides SETEN MCB, suitable for LEGRAND, SIEMENS,MG, HANGER, ABB, CLIPSAL, MITSUBISHI,
Consumer units
Metal-surface or flush mounting
Metal flush mounting
Metal surface mounting
TPN MCB board w/o main switch space
TPN MCB board C/W AL type main switch & RCD switch space
TPN MCB board C/W MCCB type main switch & RCD switch space
TPN MCB board C/W AL type main switch & RCD switch space-split bar type
Fuse Holder and Links
Catalogue Number | Fuse link size | Link current | Pole | Packing unit (link) |
STF-63/P+N | D02 | 2A,4A,6A 10A,16A | 1P | 20 |
STF-63 | D02 | 2A,4A,6A,10A 16A,20A,25A 35A,50A,63A | 1P,2P,3P,4P | 20 |
STF-63 |
|
Standard | Confirming to EN / IEC60947-3 EN / IEC60269 |
Electric ratings | Up to 63A 230V AC 50/60Hz |
Utilization category | AC-21A |
Rated insulation voltage | Ui 690V |
Rated impulse withstand voltage | 4000V |
Electric endurance | 1500 |
Mechanical endurance | 8500 |
Operating frequency | 120/h |
Protection degree | IP20 |
Metal Distribution Board
Type | Descroption | Pole configuration | Outgoing ways |
STDM2-4 | 4 way TPN 125A | TPN | 4 |
STDM2-6 | 6 way TPN 125A | TPN | 6 |
STDM2-8 | 8 way TPN 125A | TPN | 8 |
STDM2-12 | 12 way TPN 125A | TPN | 12 |
STDM1-16 | 16 way TPN 125A | TPN | 16 |
Technical Data
In compliance with standards: IEC 60439-3 and BS EN 600439-3, Galavanized 1.2mm steel sheet, High quality epoxy powder surface coating, Suitable for standard MCB, Split chassis configurations for RCD, made for special request, Besides SETEN MCB, suitable for LEGRAND, SIEMENS,MG, HANGER, ABB, CLIPSAL, MITSUBISHI,
Consumer units
Metal-surface or flush mounting
Metal flush mounting
Metal surface mounting
TPN MCB board w/o main switch space
TPN MCB board C/W AL type main switch & RCD switch space
TPN MCB board C/W MCCB type main switch & RCD switch space
TPN MCB board C/W AL type main switch & RCD switch space-split bar type
Magnetic Relay
Power Move: | 150±15%μVA,300±15%μVA. |
Operating Current : | 1.8-2.4mA, 7-9mA. |
Impedance: | 2.0Ω, 25Ω |
Thrust: | Putter trip=0.2mm,Thrust≥0.45N; Putter trip=1.6mm,Thrust≥0.25N. |
The proposed reduction of the operating agencies: | 1.2~1.3N |
Putters free trip: | >1.8mm |
largest movement time: | <20ms |
Temperature range : | -5℃-80℃ |
Life: | 5000 times |
Weight: | 8g |
Application scope
This magnetic relay is suitable for Residual Current Circuit Breaker pro ducts.
Product's advantage
•This products have the guarantee period of 6 calendar months,that is a high quality and reliability;
•This products have an excellent ratio between price and quality ,you can possess them by competitive price and high quality;
• The deliveries exactly in accordance with customer orders
•The fast transportation.
Extention Terminal
Catalogue Number | Head-width/ head-lenght | Quantity(box) | Serial No | Box specification (cm) |
STF/25-K | 4×11.5 | 2000 | 225 01 | 36×23×21 |
Rated current: 63A
Poles: 1,2,3,4P
1.Our products have the guarantee period of 36 calendar months,that is a high quality and reliability;
2.our products have an excellent ratio between price and quality ,you can possess them by competitive
price and high quality;
3.The fast and flexible production form aim at the customer require;
4.The deliveries exactly in accordance with customer orders
5.The fast transportation.
Modular Socket
Catalogue Number | Rated current (A) | Standard | Width (mm) | Connection capacity |
STP7 | 10,16,25 | France | 44.5 | ≤ 6mm2 |
STP20 | 10,16,25 | Germany | 44.5 | ≤ 6mm2 |
Frequency: 50 or 60Hz
Electrical life: 5000times
Rated insulation voltage Ui:500V
Rated impulse withstand voltage
Uimp:5000V
Dielectric test voltage at ind. Freq.
For 1 min.: 2.8kV
Mounting category: Ⅱ,Ⅲ
Pollution degree:2
Protection class: IP20
Standard mounting: 35mm DIN rail
Ambient temperature: -5℃ to +40℃
Storage temperature: -25℃to +70℃
STP7 and STW 20 Modular Socket can be used together with our other modular products for connection
of mobile devices, tools or electric and electronic non-modular equipments directly inside civil and industrial switchboards.
IP Rated & Metal Enclosures
Catalogue Number | Description | Modules |
CUE4 | Insulated - IP30 | 4 |
CUE4M | Metal - IP30 | 4 |
CUE5W | Weatherproof - IP55 | 5 |
CUGAR1 | Garage Kit - IP55, 40A 30mA RCD, 6+32A MCB | 5 |
CUSHOW1 | Shower Kit - IP55, 63A 30mA RCD, 50A MCB | 5 |
• Choice of insulated and metal enclosures
• Enclosures either IP30 or IP55 (weatherproof)
• Available in 4 or 5 modules
• Enclosures supplied with DIN rail and neutral and earth terminals
• Enclosure kits supplied complete with devices, DIN rail, neutral cable, neutral and earth terminals, and busbar
• All Seten devices can be used with enclosures, except RCBOs
• Manufactured and tested to BS EN 60439