• Consumer Units

    Catalogue 

    Number

    Dual Split Load Consumer Units

    Modules

    STDB1086

    8Way Dual Split Load Board complete

    With 2X63A RCDs and 1X100 Amp DP Isolator

    8

    STDB1088

    8Way Dual Split Load Board complete

    With 2X80A RCDs and 1X100 Amp DP Isolator

    8

    STDB1126

    12Way Dual Split Load Board complete

    With 2X63A RCDs and 1X100 Amp DP Isolator

    12

    STDB1128

    12Way Dual Split Load Board complete

    With 2X80A RCDs and 1X100 Amp DP Isolator

    12

    STDB1165

    16Way Dual Split Load Board complete

    With 2X63A RCDs and 1X100 Amp DP Isolator

    16

    STDB1168

    16Way Dual Split Load Board complete

    With 2X80A RCDs and 1X100 Amp DP Isolator

    16

    STDB1226

    22Way Dual Split Load Board complete

    With 2X63A RCDs and 1X100 Amp DP Isolator

    22

    STDB1228

    22Way Dual Split Load Board complete

    With 2X80A RCDs and 1X100 Amp DP Isolator

    22

    STDB1306

    30Way Dual Split Load Board complete

    With 2X63A RCDs and 1X100 Amp DP Isolator

    30

    STDB1308

    30Way Dual Split Load Board complete

    With 2X80A RCDs and 1X100 Amp DP Isolator

    30


    The SETEN range of insulated domestic consumer units have a modern style designed to match SETEN wiring devices. They support compliance with the latest 17th Edition Wiring Regulations, with flexibility designed in to provide maximum circuit combinations, and have been designed to provide the fastest and simplest installation.

    Available in insulated and metal versions (metal versions have metal base and insulated cover and visor. Allow for protected and unprotected ways, with a choice of Main Switch,Split load (one RCD), Dual RCD and option for three RCDs in 30 module unit.


  • IP Rated & Metal Enclosures

    Catalogue 

    Number

    Description

    Modules

    CUE4

    Insulated - IP30

    4

    CUE4M

    Metal - IP30

    4

    CUE5W

    Weatherproof - IP55

    5

    CUGAR1

    Garage Kit - IP55, 40A 30mA RCD, 6+32A MCB

    5

    CUSHOW1

    Shower Kit - IP55, 63A 30mA RCD, 50A MCB

    5


    • Choice of insulated and metal enclosures

    • Enclosures either IP30 or IP55 (weatherproof)

    • Available in 4 or 5 modules

    • Enclosures supplied with DIN rail and neutral and earth terminals

    • Enclosure kits supplied complete with devices, DIN rail, neutral cable, neutral and earth terminals, and busbar

    • All Seten devices can be used with enclosures, except RCBOs

    • Manufactured and tested to BS EN 60439


  • Metal Distribution Board

    Transparent

    Teakwood

    Wallnut

    Outgoing

    ways

    STDB4-T08

    STDB4-K08 

    STDB4-W08

    8

    STDB4-T12

    STDB4-K12

    STDB4-W12

    12

    STDB4-T16

    STDB4-K16

    STDB4-W16

    16


    Technical Data 

    In compliance with standards: IEC 60439-3 and BS EN 600439-3Galavanized 1.2mm steel sheetHigh quality epoxy powder surface coatingSuitable for standard MCBSplit chassis configurations for RCD, made for special requestBesides SETEN MCB, suitable for  LEGRAND, SIEMENS,MG, HANGER, ABB, CLIPSAL, MITSUBISHI

    Consumer units

    Metal-surface or flush mounting

    Metal flush mounting

    Metal surface mounting

    TPN MCB board w/o main switch space

    TPN MCB board C/W AL type main switch & RCD switch space

    TPN MCB board C/W MCCB type main switch & RCD switch space

    TPN MCB board C/W AL type main switch & RCD switch space-split bar type

  • Metal Distribution Board

    Type

    Descroption

    Pole

    configuration

    Outgoing

    ways

    STDM2-4

    4 way TPN 125A 

    TPN

    4

    STDM2-6

    6 way TPN 125A

    TPN

    6

    STDM2-8

    8 way TPN 125A

    TPN

    8

    STDM2-12

    12 way TPN 125A

    TPN

    12

    STDM1-16

    16 way TPN 125A

    TPN

    16


    Technical Data 

    In compliance with standards: IEC 60439-3 and BS EN 600439-3Galavanized 1.2mm steel sheetHigh quality epoxy powder surface coatingSuitable for standard MCBSplit chassis configurations for RCD, made for special requestBesides SETEN MCB, suitable for  LEGRAND, SIEMENS,MG, HANGER, ABB, CLIPSAL, MITSUBISHI

    Consumer units

    Metal-surface or flush mounting

    Metal flush mounting

    Metal surface mounting

    TPN MCB board w/o main switch space

    TPN MCB board C/W AL type main switch & RCD switch space

    TPN MCB board C/W MCCB type main switch & RCD switch space

    TPN MCB board C/W AL type main switch & RCD switch space-split bar type


  • STB1-63 Mini Circuit Breaker

    SPECIFICATIONS

    Tripping

    Curve

    Rated

    current (A)

    Pole

    Voltage (V)

    Breaking

    capacity (A)

    Standard

    6A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    6000

    IEC60898

    10A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    6000

    IEC60898

    16A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    6000

    IEC60898

    20A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    6000

    IEC60898

    25A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    6000

    IEC60898

    32A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    6000

    IEC60898

    40A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    6000

    IEC60898

    50A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240

    4500

    IEC60898

    63A

    B.C.D

    1 to 63

    1,2, 3, 4

    400/415

    4500

    IEC60898


    STB1-63 series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short-circuit in the system. The product novel in structure, light in  weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly and its installation uses with guide, its case and items are adopted with high fire-resistant and shockproof  plastic. The product, with long life, is mainly used in AC 50/60Hz single-pole 240V or two, three, four-pole 415V circuit for overload and short-circuit protection as well as for unfrequent on-and-off  switching electric equipment and lighting circuit in normal case. This product conform with GB10963, IEC60898.

  • STB1-63H Mini Circuit Breaker

    SPECIFICATIONS

    Tripping 

    Curve

    Rated 

    current (A)

    Pole

    Voltage (V)

    Breaking 

    capacity (A)

    Standard

    6A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    10000

    IEC60898

    10A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    10000

    IEC60898

    16A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    10000

    IEC60898

    20A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    10000

    IEC60898

    25A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    10000

    IEC60898

    32A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    10000

    IEC60898

    40A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    10000

    IEC60898

    50A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    10000

    IEC60898

    63A

    B.C.D

    1 to 63

    1,2, 3, 4

    240/240400/415

    10000

    IEC60898


    STB1-63 series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short-circuit in the system. The product novel in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly and its installation uses with guide, its case and items are adopted with high fire-resistant and shockproof plastic. The product, with long life, is mainly used in AC 50/60Hz single-pole 240V or two, three, four-pole 415V circuit for overload and short-circuit protection as well as for unfrequent on-and-off switching electric equipment and lighting circuit in normal case. This product conform with GB10963, IEC60898.

  • STB1-DPN Miniature Circuit Breaker

    Catalogue 

    Number

    Tripping 

    Curve

    Rated 

    current (A)

    Pole

    Voltage (V)

    Breaking 

    capacity (A)

    Standard

    STB1-DPN

    B.C.D

    1 to 40

    1P+N

    230

    4500

    IEC60898



  • STB1-100H Miniature Circuit Breaker

    Catalogue 

    Number

    Tripping 

    Curve

    Rated 

    current (A)

    Pole

    Voltage (V)

    Breaking 

    capacity (A)

    Standard

    STB1-100H

    B.C.D

    1 to 125

    1P+N

    230/400VAC

    10000

    IEC60947-2


    STB1-100H mini circuit breaker is used in AC 50Hz or 60Hz, single phase 230/240V, three phase 400/415V to protect the circuit against overload and short circuit. It can be used in lighting and motor circui t. It can also be used for infre quent switch on and off of the lighting and equipment under normal condition. The breaking capacity is 10kA according to IEC60947-2.

  • STR1 Series Residual Current Circuit Breaker

    Catalogue 

    Number

    Rated 

    Current (A)

    Number 

    of Pole

    Rating

    Type 

    Un(V)

    IΔc(A)

    STR1-63/2P  

    16,20,25,32,

    40,50,63

    2P

    10,30,

    100,300

    AC,A

    230VAC

    6000

    STR1-63/4P 

    16,20,25,32,

    40,50,63

    4P

    10,30,

    100,300

    AC,A

    400VAC

    6000


    The RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault circuit immediately on the occasion of shock hazard of earth leakage of trunk line. Thus, it  is suitable to avoid the shock hazard and fire caused by earth leakage. The RCCB is mainly suitable for useing in varieties of plants and enterprises, buildings constructions. It can be used in circuits up to 1 phase 230V and 3 phase 400V 50/60Hz. RCCB is not suitable for use on DC pulse system.

  • STR1-H Series Residual Current Circuit Breaker

    Catalogue 

    Number

    Rated 

    Current (A)

    Number 

    of Pole

    Rating

    Type 

    Un(V)

    IΔc(A)

    STR1-63H/2P  

    16,20,25,32,

    40,50,63,80,100

    2P

    10,30,

    100,300

    AC,A

    230VAC

    10000

    STR1-63H/4P 

    16,20,25,32,

    40,50,63,80,100

    4P

    10,30,

    100,300

    AC,A

    400VAC

    10000


    The RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault circuit immediately on the occasion of shock hazard of earth leakage of trunk line. Thus, it  is suitable to avoid the shock hazard and fire caused by earth leakage. The RCCB is mainly suitable for useing in varieties of plants and enterprises, buildings constructions. It can be used in circuits up to 1 phase 230V and 3 phase 400V 50/60Hz. RCCB is not suitable for use on DC pulse system.

  • STBL1-40 Residual Current Operated Circuit Breaker

    Catalogue 

    Number

    Rated 

    Current (A)

    Number 

    of Pole

    Rating

    Type 

    Un(V)

    IΔc(A)

    STBL1-40  

    6,10,16,20,

    25,32,40

    1P+N

    10,30,

    100,300

    AC,A

    230VAC

    6000


    • Stylish modern profile, matches all other SETEN devices • Double pole module• Positive contact status indicator • Available from 6 to 40A rating • Available in B,C type • Lockable dolly switch 

  • STBL1-63 Residual Current Operated Circuit Breaker

    Catalogue 

    Number

    Rated 

    Current (A)

    Number 

    of Pole

    Rating

    Type 

    Un(V)

    IΔc(A)

    STBL1-63

    6,10,16,20,

    25,32,40,63

    1P+N,2P,3P,

    3P+N,4P

    30,100,300

    AC,A

    240V/415V

    6000,

    10000


    STBL1-63 RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage 240V/415V. When an electric shock or the residual current of the circuit exceeds the threshold value, the RCBO can cut off the power within the time of 0.ls to protect the personal safety and prevent the equipment from the fault result by the residual current. Combined with MCB RCBO, it can also protect the circuit against overload and short circuit.It conforms to IEC61009 standard.

  • Residual Current Operated Circuit Breaker

    Catalogue 

    Number

    Rated 

    Current (A)

    Number 

    of Pole

    Rating

    Type 

    Un(V)

    IΔc(A)

    STNLE-32

    6,10,16,20,

    25,32

    1P+N

    10,30,

    100,300

    AC,A

    230VAC

    4500

    STBR1-40

    6,10,16,20,

    25,32

    1P+N

    10,30,

    100,300

    AC,A

    230VAC

    6000,

    10000


    • Stylish modern profile, matches all other SETEN devices • Simple pole module• Positive contact status indicator • Available from 6 to 40A rating • Available in B,C type • Lockable dolly switch 

    STBR-40
  • Circuit Breaker Accessories

    Catalogue 

    Number

    Electric 

    endurance

    Rated insulation 

    voltage

    Mechanicalendurance

    Voltage (V)

    Dielectric 

    strength

    Standard

    STBA-OF

    30000

    Ui 500V

    40000

    230VAC

    2000V/1min

    IEC 60947-5-1

    STBA-SD

    30000

    Ui 500V

    40000

    230VAC

    2000V/1min

    IEC 60947-5-1

    STBA-MX

    30000

    Ui 500V

    40000

    230VAC

    2000V/1min

    IEC 60947-5-1

    STBA-MN

    30000

    Ui 500V

    40000

    230VAC

    2000V/1min

    IEC 60947-5-1


    OF Auxiliary contactContact capacity:AC:Un=400V In=3AUn=230V In=6ADC:Un=125V In=1AUn=48V In=2AUn=24V In=6ADielectric strength:2000V/1minMounted on the left side of the MCB STB1-63H.


    SD Alarming contactSend out signals when the circuit breaker pail to trips.Mechanical indicator on the front panel, which can indicate failure trip.Screw-type thread pressed terminal,can connect with 1 or 2 conductiong wire of 2.5 mm2 max.cross sectional area.Obvious marks upon terminal.Mounted on the left side of the MCB STB1-63H.indication"ON","OFF" status of combined MCB.


    MX Shunt trip Rated insulating voltage(Ui):500VRated power voltage(Us):AC 400,230,125VOperate voltage range:70~100% UsContact capacity: AC:3A/400V AC:6A/230VAC:9A/125V Dielectric strength:2000V/1minMounting on the right side of MCB/RCBO, used to trip the combined MCB/RCBO by remotecontrolling device.


    MN Over-voltage/undervoltage trip Rated voltage(Ue):AC 230VRated insulating voltage(Ui):500VOver-voltage tripping range:280V±5%Under-voltage tripping range:170V±5%Mounted on the right side of circuit breaker, actuate the combined device to trip in case of undervoltageor over-voltage, effectively prevent the device from closing operation under abnormalpower voltage condition.



    Shunt & MN
    Auxiliary & Alarming
  • STI1 Isolating Switch

    Catalogue 

    Number

    Rated 

    current (A)

    Number 

    of Pole

    Un(V)

    Utilization category

    STI1

    16,20,25,32,40,50,63,80,100,125

    1P,2P,3P,4P

    230/400VAC

    AC-22A


    STI1 main switch is designed to accept cable-in/cable-out connections. It may be used as an isolating switch. The switch disconnected is capable of switching both resistive and inductive loads.The product conforms to IEC60947-3.

  • Fuse Holder and Links

    Catalogue 

    Number

    Fuse link size

    Link current

    Pole

    Packing

    unit (link)

    STF-32/P+N

    8.5×31.5mm

    2A,4A,6A

    10A,16A

    1P

    20

    STF-32

    10×38mm

    2A,4A,6A,10A

    16A,20A,25A

    32A

    1P,2P,3P,4P

    20



    STF-32

      

    Standard

    Confirming to EN / IEC60947-3 

    EN / IEC60269

    Electric ratings

    Up to 32A 230V AC 50/60Hz

    Type

    SGF-32 (Without indicator); 

    SGF-32X (With indicator)

    Utilization category

    AC-22A

    Rated insulation voltage

    Ui 500V

    Rated impulse withstand voltage

    4000V

    Electric endurance

    1500

    Mechanical endurance

    8500

    Operating frequency

    120/h

    Protection degree 

    IP20

  • Fuse Holder and Links

    Catalogue 

    Number

    Fuse link size

    Link current

    Pole

    Packing

    unit (link)

    STF-63/P+N

    D02

    2A,4A,6A

    10A,16A

    1P

    20

    STF-63

    D02

    2A,4A,6A,10A

    16A,20A,25A

    35A,50A,63A

    1P,2P,3P,4P

    20



    STF-63

      

    Standard

    Confirming to EN / IEC60947-3 

    EN / IEC60269

    Electric ratings

    Up to 63A 230V AC 50/60Hz

    Utilization category

    AC-21A

    Rated insulation voltage

    Ui 690V

    Rated impulse withstand voltage

    4000V

    Electric endurance

    1500

    Mechanical endurance

    8500

    Operating frequency

    120/h

    Protection degree 

    IP20


  • Indicating Light

    Catalogue 

    Number

    Color

    Life

    Voltage (V)

    Altitude

    Mounting

    Standard

    ST1SL

    Red,

    green,

    yellow,

    orange,blue,

    white

    incandescence lamp ≥1000h

    neon lamp≥2000h

    LED≥30000h

    230VAC 50/60Hz

    not exceed 

    2000m

    On 35mm 

    DIN rail

    IEC 60947-5-1


    The Modular Signal is applicable to circuit with rated voltage 230Vand frequency 50/60Hz for visual indication and signaling.

  • Door Bell

    Catalogue 

    Number

    Installation 

    class

    Pollution grade

    Working 

    condition

    Electric ratings

    Mounting

    Standard

    ST1SO

    II & III

    ll

    Short-time

    8V,12V,

    24V,110V, 

    230V,

    50/60Hz

    On 35mm 

    DIN rail

    IEC61558-1


    Application scopeST1SO be applicable to circuit with rated voltage 230V, rated frequency 50Hz/60Hz and rated current not exceeding 63A, providing the function of sound warning and prompting.

  • Transformer

    Catalogue 

    Number

    Transformer 

    out 

    power 

    capacity

    Non-load 

    current 

    Io(mA)

    Non-load 

    wastage 

    Po(w)

    Output 

    voltage

    Input 

    voltage

    Standard

    ST1TF

    3.8VA8VA

    36±6

    1.12

    4V, 6V, 8V, 

    12V,16V,24V

    230/240V

    50/60Hz

    IEC61558-1


    Application scopeBell transformer is applicable to circuit of AC 50Hz, operating voltage up to 250V. With output power capacity 3.8VA and 8VA, the product functions as ideal and safe power supply for household door bell.

  • STTM-16 time switch


    Type:electromechanical type with time delayTime setting range: 7 minutesMin.setting interval: 30 secondsToggle switch: manual/automaticControlled lighting load:Incandescent lamp: 2300WHalogen lamp: 2300WFluorescent lamp:Uncompensated 2300wCompensated in series: 2300wCompensated in parallel: 1300wSwitching: reset after 30s

  • STTM-E8 time switch


    Type: electronic time delayTime setting range: 20 minutesMin.setting interval: 5 minutesSlide switch: manual/automaticControlled lighting load:Incandescent lamp: 2300WHalogen lamp: 2300WFluorescent lamp load with electronic ballast: 800WSwitching: immediate reset

  • time switch TM160


    STTM-160 Synchronous time switchDrive: synchronous motorFrequency: 50/60HzWithout batterySTTM-180 Quartz time switch with power reserveDrive: quartz-controlled motorFrequency: 50/60HzAccuracy: within±1s per day at 20oCReserve: 70 hoursTechnical DateConsumption: 2.5VAContact: 1NOContact capacity:16A/250V AC (COSφ=1)4A/250V AC (COSφ=0.6)Electrical endurance: 105 cyclesMechanical endurance: 107 cycles24 hours 96 segmentsmin.programmable interval: 15minutesAmbient temperature: -10oC~+50oC

    STTM180.jpg
  • time switch STM161H


    STM161H Synchronous time switchDrive: synchronous motorFrequency: 50/60HzSTT2-181h Quartz time switch with power reserveDrive:quartz-controlled motorFrequency: 50/60HzAccuracy: within±1s per day at 20oCReserve: 150 hoursTechnical DateConsumption: 2.5VAContact capacity: 16A/250V ACcyclesElectrical endurance: 105 cyclesMechanical endurance: 107 cycles24 hours program 48 segmentsmin.programmable interval: 30minutesAmbient temperature: -20oC~+50oC

  • STTM time switch STM15


    STM15 Type: electronic with LCD displayRated voltage: 230V ACRated frequency: 50/60HzContact: 1NO+1NCConsumption: maximun 4VAContact capacity:16A/250V AC (COSφ=1)2.5A/250V AC (COSφ=0.6)Incandescent lamp: 1000WElectrical endurance: 105 cyclesMechanical endurance: 107 cyclesTime basis: quartz24 hours + week programWorking precision: ≤2 sec/day(25oC)min.programmable interval: 1minutesPower reserve:min. 15 daysAmbient temperature: -10oC~+40oCHumidity: 35-85%RH

  • Measuring Device


    Standard

    Rated insulation

    Temperature range

    Terminal capacity(Max)

    Type of terminal

    Module width

    Confirming to EN / IEC60051-1-2

    600V AC

    -25oC~+40oC

    6mm2

    Pin type

    36mm


    STPM-45A Ammeter

    Rated Frequency: 50Hz

    Power Consumption: 1.5VA

    Accuracy: Class 1.5

    Temperature Range: -25oC~+40oC

    Insulation Voltage: 600V


    STPM-45V Voltmeter

    Rated Frequency: 50Hz

    Power Consumption: 3.5VA

    Range: 0-600V.0-300V

    Accuracy: Class 2.5

    Temperature Range: -25oC~+40oC

    Insulation Voltage: 600V


    STPM-D45A Ammeter

    Display: 3 1/2 Digitals

    Accuracy: 0.5%

    Standards: EN / IEC60051-1-2

    Rated current: 0-10A AC,0-5A AC

    Auxiliary voltage: 115/230V 50Hz

    Power consumption: 1.8VA

    Rated frenquency: 50Hz

    Insulation voltage: 660V

    Test voltage at 50Hz 1 min: 2000V

    Terminal capacity(Max): 4mm2


    STPM-D45V Voltmeter

    Display: 3 1/2 Digitals

    Accuracy: 0.5%

    Standards: EN / IEC60051-1-2

    Rated voltage: 600VAC

    Auxiliary voltage: 115/230V 50Hz

    Power consumption: 1.8VA

    Rated frenquency: 50Hz

    Insulation voltage: 660V

    Test voltage at 50Hz 1 min: 2000V

    Terminal capacity(Max): 4mm2



  • STDS-1 Series Single-phase DIN-Rail electronic energy meter


    One module

    Model: LCD 10100L
    Counter 10100M
    Rated Voltage: 110V,220V,230V,240V
    Rated Current: 5(32)A,5(40)A,5(45)A,5(50)A
    Accuracy Class: 1.0
    Frequency: 50/60Hz
    Impulse Constant: 1000imp/kWh,2000imp/kWh
    Display: LCD,Counter
    Power Consumption: ≤8VA,≤0.4W
    Start Current: 0.4%Ib
    Connection Mode: Direct type
    Standard: IEC62052-11,IEC62053-21
    DIN EN 50022,DIN43880


    Two module
    Model: LCD 20100L
    Counter 20100M
    Rated Voltage: 110V,220V,230V,240V
    Rated Current: 5(32)A,5(40)A,5(50)A,5(80)A
    Accuracy Class: 1.0, 2.0
    Frequency: 50/60Hz
    Impulse Constant: 1000imp/kWh,2000imp/kWh
    Display: LCD,Counter
    Power Consumption: ≤8VA,≤0.4W
    Start Current: 0.4%Ib
    Connection Mode: Direct type
    Standard: IEC62052-11,IEC62053-21
    DIN EN 50022,DIN43880


    Four module
    Model: LCD 40100L direct type
    LCD 40200L CT type
    Counter 40100M direct type
    Counter 40200M CT type
    Rated Voltage: 110V,220V,230V,240V
    Rated Current: 1.5(6)A,5(20)A,5(30)A,10(40)A,15(60)A,20(80)A,10(100)A
    Accuracy Class: 1.0
    Frequency: 50/60Hz
    Impulse Constant: 800imp/kWh,1600imp/kWh,12000imp/kWh
    Display: LCD,Counter
    Power Consumption: ≤1W(when 220V 20A)
    Start Current: 0.4%Ib
    Connection Mode: Direct type, CT type
    Creep: Anti-creeping
    Standard: IEC62052-11,IEC62053-21
    DIN EN 50022,DIN43880


    Seven module
    Model: LCD G0100L direct type
    LCD G0200L CT type
    Counter G0100M direct type
    Counter G0200M CT type
    Rated Voltage: 3X110/180V,3X220/380V,3X230/400V
    Rated Current: 1.5(6)A,5(20)A,10(40)A,20(80)A,10(100)A
    Accuracy Class: 1.0,2.0
    Frequency: 50/60Hz
    Impulse Constant: 800imp/kWh,1600imp/kWh,12800imp/kWh
    Display Mode: LCD,Counter
    Power Consumption: ≤2W,10VA
    Start Current: 0.4%Ib
    Connection Mode: Direct type,CT type
    Creep: Its output is less than one impulse when the voltage
    is 115% voltage rating,the circuit doesn't has any current.
    Standard: IEC62052-11,IEC62053-21
    DIN EN 50022,DIN43880


    Five module
    Model: LCD E020CL CT type
    Rated Voltage: 3X220/380V,3X230/400V
    Rated Current: 1.5(6)A
    Accuracy Class: 1.0
    Frequency: 50/60Hz
    Impulse Constant: 12000imp/kWh
    Display: LCD 6+2/7+1/8+0
    Power Consumption: ≤1W≤7VA
    Start Current: 0.4%Ib
    Connection Mode: CT type, CT ratio
    Display Digits 6+2: 5/5,10/5,20/5,25/5,40/5,50/5,60/5
    7+1: 75/5,80/5,100/5,120/5,150/5,200/5,250/5,300/5,400/5,500/5,600/5
    8+0: 800/5,1000/5,1200/5,1500/5,2000/5,2500/5,3000/5,4000/5,5000/5,6000/5
    Standard: IEC62052-11,IEC62053-21
    DIN EN 50022,DIN43880

    电表3.jpg
    电表4.jpg
    电表2.jpg
    电表1.jpg
    电表5.jpg
  • Modular Contactor

    Catalogue

    Number

    Rated current(A)

    Number of

    contacts

    Packing unit

    STC1 2P(16A-25A)

    16,20,25

    1NO

    1NC

    1NO+1NC

    12

    STC1 2P(32A-63A)

    32,40,63

    1NO

    1NC

    1NO+1NC 

    6

    STC1 4P(16A-25A)

    16,20,25

    4NO

    4NC

    2NO+2NC

    3NO+1NC

    6

    STC1 4P(32A-63A)

    32,40,63

    4NO

    4NC

    2NO+2NC

    3NO+1NC

    4


    Technical data

    Standard: IEC/EN 60947-4-1,IEC/EN 61095

    Maxim power: 

    AC1 220/230VAC:20A 4.5KW(STC1-20)

    AC1 220/230VAC:25A 16KW(STC1-25)

    AC1 380/400VAC:63A 40KW(STC1-63)

    AC3 380/400VAC:27A 15KW(STC1-63),

    AC3 380/400VAC:27A4KW(STC1-25)

    Main contacts terminal capacity: 

    1.5-10mm2(STC1-20/STC1-25)

    2.5-25mm2(STC1-63)

    Coil contact A1,A2 terminal capacity: 0.75-2.5mm2

    Electric endurance: ≥3×104

    Mechanical endurance: ≥3×105

    Protection degree: IP20


  • Surge Protective Device

    Type

    Poles

    Uc(V)

    In(KA)

    Imax(KA)

    Up(KV)

    Applicable grounding

    system

    STS1-D/1-140-5

    12

    140

    20

    40

    0.8

    Under AC110V and DC

    STS1-D/1-275-5

    12

    275

    20

    40

    1.2

    TN-C, IT, TN-S

    STS1-D/1-320-5

    12

    320

    20

    40

    1.5

    TN-C, IT, TN-S

    STS1-D/1-385-5

    12

    385

    20

    40

    1.8

    TT

    STS1-D/1-420-5

    12

    420

    20

    40

    2.0

    TT

    STS1-D/2Q-385-5

    3

    385

    20

    40

    2.0

    STS1-D/3N-275-5

    3

    275

    20

    40

    1.2

    "3+1" Compage

    STS1-D/3N-320-5

    3

    320

    20

    40

    1.5

    "3+1" Compage

    STS1-D/4-275-5

    4

    275

    20

    40

    1.2

    TN-C, IT, TN-S

    STS1-D/4-320-5

    4

    320

    20

    40

    1.5

    TN-C, IT, TN-S

    STS1-D/4-385-5

    4

    385

    20

    40

    1.8

    TT

    STS1-D/4-420-5

    4

    420

    20

    40

    2.0

    TT


    Technical data

    Standard: Confirming to IEC61643-1

    Protection: Protect electric system and on-loading electrical apparatus

    from thunder and instantaneous over-voltage

    Ambient temperature: -5oC to +45oC

    Number of poles: 1P, 2P, 3P, 4P

    Electric ratings: 230/400V, AC50/60Hz

    Response time: Less than 25ms

    On-Off indicating window: Green normal function

    Red functionless, immediate replacement required

    Pollution grade: ll

    Installation class: l, ll, lll

    Type of terminal: Pin type

    Terminal capacity: Solid wire cross-seetion is 1-6mm2

    Stranded wire cross-section is 0.75-4mm2

    Installation: Mounting on 35mm DIN rail

    Width: 17.5mm per pole

    Ground system: "TT, TN-S, TN-C-S"are applicable to the ground system of the protector


  • Surge Protective Device

    Rated voltage (V)

    220/380

    Continuous operating voltage (one-pole) (V)

    385~420

    Pole no.

    2,3,4

    8/20µ s nominal discharge current (kA)

    40,60,80,100

    8/20µ s maximum discharge current (kA)

    80,100,120,150

    10/350µ s impulse discharge current (kA)

    8,10,12,15,

    Electric charge quantity (As)

    2.0, 2.5, 3.75, 5.0

    Voltage protective level (kV)

    2.0, 2.0, 2.0.5, 3.0

    Response time (ns)

    < 25

    Suggested connecting wire size (mm 2 )

    L, N hard wire 16, PE 25 hard wire

    Suggested fuse current (A)

    63~100

    One-pole width (mm)

    18,27,27,27,

    Installation

    Electric track of 35mm

    Type demonstration

    LND-B/4-420-60


    Technical data

    Standard: Confirming to IEC61643-1

    Protection: Protect electric system and on-loading electrical apparatus

    from thunder and instantaneous over-voltage

    Ambient temperature: -5oC to +45oC

    Number of poles: 1P, 2P, 3P, 4P

    Electric ratings: 230/400V, AC50/60Hz

    Response time: Less than 25ms

    On-Off indicating window: Green normal function

    Red functionless, immediate replacement required

    Pollution grade: ll

    Installation class: l, ll, lll

    Type of terminal: Pin type

    Terminal capacity: Solid wire cross-seetion is 1-6mm2

    Stranded wire cross-section is 0.75-4mm2

    Installation: Mounting on 35mm DIN rail

    Width: 17.5mm per pole

    Ground system: "TT, TN-S, TN-C-S"are applicable to the ground system of the protector


  • Modular Socket

    Catalogue 

    Number

    Rated current

    (A)

    Standard

    Width

    (mm)

    Connection 

    capacity

    STP7

    10,16,25

    France

    44.5

    ≤ 6mm2

    STP20

    10,16,25

    Germany

    44.5

    ≤ 6mm2


    Frequency: 50 or 60Hz

    Electrical life: 5000times

    Rated insulation voltage Ui:500V

    Rated impulse withstand voltage 

    Uimp:5000V

    Dielectric test voltage at ind. Freq. 

    For 1 min.: 2.8kV


    Mounting category: Ⅱ,Ⅲ

    Pollution degree:2

    Protection class: IP20

    Standard mounting: 35mm DIN rail

    Ambient temperature: -5℃ to +40℃

    Storage temperature: -25℃to +70℃


    STP7 and STW 20 Modular Socket can be used together with our other modular products for connection 

    of mobile devices, tools or electric and electronic non-modular equipments directly inside civil and industrial switchboards. 


  • Insulated Busbars

    Catalogue

    Number

    Inserting

    method

    Current

    ratings(A)

    Poles No.

    Cross

    section(mm)

    Length(mm)

    ST-BB101

    Pin type

    63/1

    56×1

    20

    100

    ST-BB102

    U type

    63/1

    56×1

    20

    100

    ST-BB201

    Pin type

    63/2

    27×2

    20

    100

    ST-BB202

    U type

    63/2

    27×2

    20

    100

    ST-BB301

    Pin type

    63/3

    18×3

    20

    100

    ST-BB302

    U type

    63/3

    18×3

    20

    100

    ST-BB401

    Pin type

    63/4

    14×4

    20

    100

    ST-BB402

    U type

    63/4

    14×4

    20

    100


    Application

     Make wiring of electrical item easy, enlarge connection area,decrease temperature rise

    Characteristics

    The busbars make wiring of electrical item easy, enlarge connection area, decrease temperature rise and increase the electrical reliability of electrical items.

    Current rating up to 63 A, rated voltage up to 415 V.


  • Extention Terminal

    Catalogue 

    Number

    Head-width/

    head-lenght

    Quantity(box)

    Serial No

    Box 

    specification

    (cm)

    STF/25-K

    4×11.5

    2000

    225 01

    36×23×21


    Rated current: 63A

    Poles: 1,2,3,4P

    1.Our products have the guarantee period of 36 calendar months,that is a high quality and reliability;
    2.our products have an excellent ratio between price and quality ,you can possess them by competitive 

      price and high quality;
    3.The fast and flexible production form aim at the customer require;
    4.The deliveries exactly in accordance with customer orders
    5.The fast transportation. 


  • Magnetic Relay

    Power Move:

    150±15%μVA300±15%μVA.

    Operating Current : 

    1.8-2.4mA, 7-9mA.

    Impedance: 

    2.0Ω, 25Ω

    Thrust:

    Putter trip=0.2mmThrust≥0.45N;

    Putter trip=1.6mmThrust≥0.25N.

    The proposed reduction

    of the operating agencies:

    1.21.3N

    Putters free trip: 

    >1.8mm

    largest movement time: 

    <20ms

    Temperature range : 

    -5℃-80℃

    Life: 

    5000 times

    Weight: 

    8g


    Application scope

    This magnetic relay is suitable for Residual Current Circuit Breaker pro ducts.

    Product's advantage

    •This products have the guarantee period of 6 calendar months,that is a high quality and reliability;

    •This products have an excellent ratio between price and quality ,you can possess them by competitive price and high quality;

    • The deliveries exactly in accordance with customer orders

    •The fast transportation.