• HOUR METER



    Download
  • Panel Meter


    Analogue Panel Meters
    Standard:IEC60051-1
    Approval:CE
    Accuracy:1.5/2.5
    Operating position:Vertical


    Digital Panel Meters

    Standard:ICS 17.220.20
    Approval:CE
    Accuracy:+0.5%

    Display range:0~1999

    Download
  • K.W.H. Meter Box



  • K.W.H. Meter

    Catalogue 

    Number

    Ref.
    Voltage(v)

    Ref.
    Frequency

    Rated Current

    STM71/SGM71L

    120V220V

    230V240V

    50,60Hz

    1.5(6)A,2.5(10)A,5(20)A,5(30)A,5(60)A, 5(100)A,

    10(40)A, 10(60)A,10(100)A,15(120)A

    STM73/SGM73L

    120/240V

    50,60Hz

    1.5(6)A,2.5(10)A,5(20)A,5(30)A,5(60)A, 5(100)A,

    10(40)A, 10(60)A,10(100)A,15(120)A


    Single Phase Static Energy Meter with Tamper and Fraud

    Protection and with Register,LED or LCD Display or 485

    Interface or Infrared Interface


    General

    Single Phase Static Energy Meter is used for measuring the single phase a.c. active 

    energy. It adopts the high quality long lifetime components and SMT manufacturing craft, and is reliable in performance. It conforms to IEC 62053-21 standard: Static meters for 

    active energy (Class 1 and 2).

    Seten also can design and produce the meter as per the standards offered by the 

    buyers.


    Main Technical Parameter

    Accuracy:Class 1.0; Class 2.0

    Rated current:1.5(6)A,2.5(10)A, 5(20)A,5(30)A, 5(60), A10(40)A, 10(60)A,

    10(100)A,15(120)A

    Rated voltage(Un):120V,220 V, 230V, 240V, 120/240V

    Operation voltage:0.7Un~1.3Un

    Rated frequency:50 or 60 Hz±5%

    Max. display value:99999.9

    Power consumption:≤1.0W,8VA

    Operation temperature:-25°C~55°C

    Limited temperature:-40°C~70°C

    Operation humidity:≤100%RH

    Lifetime:>10 years


    Main function features

    High accuracy: Adopting the high quality specializing metering chip; 

    Stable errors; Good linear;

    High accuracy at low load; No need for calibration for a long term service.

    Stability and reliability: Wide range of operating voltage; Strong ability to withstand the

    disturbance, interference and overloading.

    Long lifetime: Adopting the advanced SMT manufacturing craft; High quality 

    long lifetime of main components.

    Low Power Consumption: Adopting the best design; Low self power consumption.

    Tamper and fraud protection: With the protection function of the short circuit, 

    the reversal connection of phase wire and neutral wire, and the neutral wire 

    connecting to the earth.

    Convenient installation:Simple construction; Compact design; Light weight; 

    With the same installation size of the electromechanical energy meter.


  • Three Phase Static Energy Meter Series


    Catalogue 

    Number

    Ref.
    Voltage(v)

    Ref.
    Frequency

    Rated Current

    SGM92/SGM92L

    3×110V or 3×120/208V

    3×220V or 3×220/380V

    3×230V or 3×230/400V

    3×240V or 3×240/415V

    50,60Hz

    1.5(6)A,5(20)A,5(60)A, 

    5(100)A,3×10(40)A, 

    10(100)A,15(60)A,

    3×20(80)A,3×30(100)A,

    SGM93/SGM93L

    SGM94/SGM94L


    Three Phase Static Energy Meter with Tamper and Fraud Protection and with 

    Register,LED or LCD Display or 485 Interface or Infrared Interface


    General

    Three Phase Static Energy Meter is used for measuring the three phase a.c. active energy. It adopts the high quality long lifetime components, the SMT manufacturing craft, 

    the microprocessing and Electro Magnetic Compatibility(EMC)technology, and is 

    reliable in performance. It conforms to IEC 62053-21 standard: Static meters for 

    active energy (Class 1 and 2). Maxge also can design and produce the meter as per 

    the standards offered by the buyers.


    Main Technical Parameter

    Accuracy: Class 1.0

    Rated current:3×1.5(6)A3×5(20)A3×5(100)A3×10(40)A

    3×10(100)A3×15(60)A15(120)A3×20(80)A3×30(100)A

    --5A, CT connectedetc.

    Rated voltage(Un):3×220/380V, 3×230/400V, 3×240/415V

    Operation voltage:0.7Un~1.3Un

    Rated frequency:50 or 60 Hz±5%

    Maximum display value:99999.9

    Power consumption:≤2.0W,10VA

    Operation temperature:-25°C55°C

    Limited temperature:-40°C70°C

    Operation temperature:≤100%RH

    Lifetime:>10years


  • Single Phase Induction Energy Meter Series


    Catalogue 

    Number

    Accuracy

    Ref.
    Voltage(v)

    Ref.
    Frequency

    Rated Current

    DD217

    1.0

    2.0

    120V

    220V

    230V

    240V

    50Hz

    60Hz

    50/60Hz

    2.5(10)A5(10)A

    5(20)A5(60)A

    10(20)A10(30)A

    10(40)A10(100)A

    15(60)A20(40)A

    20(80)A30(60)A

    30(100)A40(80)A

    40(120)A

    DD217C

    DD862


    Construction features

    The electromagnetic components of the meter are arranged in horizontal position, 

    and the electromagnetic parts are separated one from the other. The voltage core of 

    semi-enclosed and plugin type is used. Double jewel or magnetic bearing is used in 

    the bearing system. The register consists of five or six cyclometer or jumping type 

    drums, and the bi-directional register can be provided in order to prevent rotation reversal on request. The material of register gear can be metal or delrin.

    The material of meter base can be metal, bakelite or polycarbonate. The material of 

    meter cover can be glass, metal, ABS, polycarbonate or bakelite. The material of 

    terminal block can be bakelite or polycarbonate with 10% glassfiber. The material of 

    extended terminal block cover can be metal, ABS,polycarbonate or bakelite. Meter 

    frame is formed by die-casting aluminum alloy, and then undergoing heating process 

    to ensure the meter has the advantages of high mechanical strength and stability in

    construction. We can also design and construct the special energy meters as per the 

    requirements of the buyers with the appointed standards.


    Main Technical Parameter

    Reference temperature:23°C

    Working temperature range:-25°C to +55°C

    Limit working temperature range:-40°C to +70°C

    Store and transportation limit temperature range:-40°C to +70°C

    Connection method: Whole current direct connection

    Standards: IEC62052-11; IEC62053-11; IEC60529; IEC60514

    Lifetime:>15 years


  • Three Phase Induction Energy Meter Series


    Type

    Wire

    Accuracy

    Rated Voltage (V)

    Basic 

    Current (A)

    DT862/DT217

    3 Phase 4Wire

    1.0

    3×220/380

    3×230/400

    3×240/415

    3×1.5(6)

    3×3(6) etc.

    DT862/DT217

    3 Phase 4 Wire

    2.0

    3×220/380

    3×230/400

    3×240/415

    3×2.5(10)

    3×5(20)

    3×10(40)

    3×15(60)

    3×20(80)

    3×30(100)

    DS862/DS217

    3 Phase 3 Wire

    1.0

    3×100

    3×1.5(6)

    3×3(6) etc.

    DS862/DS217

    3 Phase 3 Wire

    2.0

    3×1003×380/400/415

    3×2.5(10)

    3×5(20)

    3×10(40)

    3×15(60)

    DX862/DX217

    3 Phase 4 Wire

    2.0, 3.0

    3×380/400/415

    3×1.5(6)

    3×3(6) etc.


    Three Phase Three Wire/Three Phase Four Wire Active

    (Reactive) Electromechanical Energy Meter with the

    Optional Maximum Demand Indicator


    Main Technical Parameter

    Reference temperature:23°C

    Working temperature range:-25°C to +55°C

    Limit working temperature range:-40°C to +70°C

    Store and transportation limit temperature range:-40°C to +70°C

    Connection method: Direct connection, CT connection or CT-VT connection

    Standards: IEC62052-11; IEC62053-11; IEC60529; IEC60514 or any appointed 

    standard appointed by buyers.


  • Single Phase Static Multirate Energy Meter Series


    DDSF21 7 Single Phase Static Multirate Energy Meter with Tamper

    and Fraud Protection and with Register,LED or LCD Display and

    RS485 or Infrared Interface

    Main Technical Parameter

    Accuracy:Class 1.0; Class 2.0

    Rated current: 1.5(6)A,2.5(10)A, 5(20)A,5(30)A, 10(40)A, 10(60)A,etc.

    Rated voltage(Un):220 V, 230V, 240V

    Operation voltage:0.7Un~1.3Un

    Rated frequency:50 or 60 Hz±5%

    Max. display value:99999.9

    Infrared communication distance: ≤4m

    Infrared communication angle: ≤15°

    Accuracy of clock: the absolute value is not more than 0.5s/d.

    Power consumption:≤1.0W

    Operation temperature:-10°C~45°C

    Limited temperature:-25°C~55°C

    Operation humidity:≤100%RH

    Lifetime:>10 years


  • Three Phase Static Multirate Energy Meter Series


    DTSF217 Three Phase Static Multirate Energy Meter with Tamper

    and Fraud Protection and with Register,LED or LCD Display and

    485 Interface or Infrared Interface

    Main Technical Parameter

    Accuracy: Class 1.0

    Rated current3×1.5(6)A3×5(20)A3×10(40)A, 3×10(60)A3×20(80)A,

    5A CT connected,etc.

    Rated voltage(Un)3×220/380V, 3×230/400V, 3×240/415V

    Operation voltage0.7Un1.3Un

    Rated frequency50 or 60Hz±5%

    Maximum display values99999.99

    Infrared communication distance: ≤4m

    Infrared communication angle: ≤15°

    Clock accuracy: The absolute values is not more than 0.5s/d.

    Power consumption≤2W

    Operation temperature:-1045

    Limited temperature-2555

    Operation humidity≤100%RH

    Lifetime>10 years


  • Single Phase Static Prepaid Energy Meter Series


    DDSY21 7 Single Phase Prepaid Energy Meter with Tamper and

    Fraud Protection and with Register,LED or LCD Display and 485

    Interface or Infrared Interface

    Main Technical Parameter

    AccuracyClass 1.0 and Class 2.0

    Rated current: 1.5(6)A, 2.5(10)A, 5(20)A,5(30)A, 1040A,10

    60A,etc.

    Rated voltage(Un)220V, 230V, 240V

    Operation voltage0.7Un1.3Un

    Rated frequency50 or 60 Hz±5%

    Maximum display values99999.9

    PoRisesunr consumption≤1.0W

    Operation temperature-2555

    Limited temperature-4070

    Working temperature≤100%RH

    Lifetime>10 years


  • Three Phase Static Prepaid Energy Meter Series


    DTSF217 Three Phase Static Prepaid Energy Meter with Tamper and

    Fraud Protection and with Register,LED or LCD Display and 485

    Interface or Infrared Interface

    Main Technical Parameter

    AccuracyClass 1.0

    Rated currentThree Phase Four Wire: 3×1.5(6)A3×5(20)A3×10(40)A

    3×20(80)ACTconnectedetc.

    Three Phase Three Wire: 3×1.5(6)A

    Rated voltage(Un)Three Phase Four Wire: 3×220/380V , 3×230/400V,

    3×240/415V Three Phase Three Wire: 3×100V

    Operation voltage: 0.7Un1.3Un

    Rated frequency50 or 60 Hz±5%

    Connection method: Three phase four wire: Direct connection or CT connected

    Three phase three wire: Potential and current transformer

    connected

    Maximum display values: 999999.9

    PoRisesunr consumption≤2.0W

    Operation temperature: -2555

    Limited temperature: -4070

    Operation humidity≤100%RH

    Lifetime >10 years


  • Single Phase Static Multifunction Energy Meter


    General

    DDSD21 7 Single Phase Electronic Multifunction Energy Meter is the latest energy meter in the 21

    century, is full electronic design and suitable for measuring the active energy either in prepaid method

    or in time-sharing payment. The meter adopts CMOS integrated circuit, micro-electronics technology

    and EMC technology. It has the simple circuit and reasonable construction.Its main features are high

    precision, high reliability, strong loading ability, low power consumption, compact volume, light weight,

    long lifetime and anti-tampering.

    Real time clock is installed inside the meter, and can distinguish automatically and display by LED the

    peak, non-peak or basis time band of the current operation, and realize the time-sharing calculating rate.

    The meter has the infrared interface through which can realize the data exchange between meter and hand

    holder controller and between meter and infrared card to accomplish the management of prepayment.

    The system with RS-485 series interface can accomplish the same function of the infrared interface.


  • Three Phase Static Multifunction Energy Meter


    General

    Three Phase Static Multifunction Energy Meter is a new type intelligent energy meter,

    designed by adopting the advanced technology as per the practical requirements of users. It is

    with the features of high accuracy, high reliability, reasonable layout, advanced craft, strong

    applicability, strong function and convenient operation, etc.. It can measure and calculate all

    kinds of electrical parameters correctly and quickly , which reaches the advanced level.

    It conforms to standards: IEC 62053-21 Static meters for active energy (Class 1 and

    2), GB/T 17883-1999 Static meters for active energy (Class 0.2S and 0.5S) and DL/

    T614 -1997 Multifunction Energy Meter. The communication protocol conforms to IEC11 07

    Communication Protocol of Multifunction Energy Meter. Maxge also can design and produce

    the meter as per the standards offered by the buyers.


  • Single-phase DIN-Rail electronic One moduleenergy meter


    Model: LCD 10100L

    Counter 10100M

    Rated Voltage: 110V,220V,230V,240V

    Rated Current: 5(32)A,5(40)A,5(45)A,5(50)A

    Accuracy Class: 1.0

    Frequency: 50/60Hz

    Impulse Constant: 1000imp/kWh,2000imp/kWh

    Display: LCD,Counter

    Power Consumption: ≤8VA,0.4W

    Start Current: 0.4%Ib

    Connection Mode: Direct type

    Standard: IEC62052-11,IEC62053-21

    DIN EN 50022,DIN43880


  • Single-phase DIN-Rail electronic Two module energy meter


    Model: LCD 20100L

    Counter 20100M

    Rated Voltage: 110V,220V,230V,240V

    Rated Current: 5(32)A,5(40)A,5(50)A,5(80)A

    Accuracy Class: 1.0, 2.0

    Frequency: 50/60Hz

    Impulse Constant: 1000imp/kWh,2000imp/kWh

    Display: LCD,Counter

    Power Consumption: ≤8VA,0.4W

    Start Current: 0.4%Ib

    Connection Mode: Direct type

    Standard: IEC62052-11,IEC62053-21

    DIN EN 50022,DIN43880


  • Single-phase DIN-Rail electronic energy meter Four module


    Model: LCD 40100L direct type

    LCD 40200L CT type

    Counter 40100M direct type

    Counter 40200M CT type

    Rated Voltage: 110V,220V,230V,240V

    Rated Current: 1.5(6)A,5(20)A,5(30)A,10(40)A,15(60)A,20(80)A,10(100)A

    Accuracy Class: 1.0

    Frequency: 50/60Hz

    Impulse Constant: 800imp/kWh,1600imp/kWh,12000imp/kWh

    Display: LCD,Counter

    Power Consumption: 1W(when 220V 20A)

    Start Current: 0.4%Ib

    Connection Mode: Direct type, CT type

    Creep: Anti-creeping

    Standard: IEC62052-11,IEC62053-21

    DIN EN 50022,DIN43880


  • Three-phase DIN-Rail electronic energy meter Seven module


    Model: LCD G0100L direct type

    LCD G0200L CT type

    Counter G0100M direct type

    Counter G0200M CT type

    Rated Voltage: 3X110/180V,3X220/380V,3X230/400V

    Rated Current: 1.5(6)A,5(20)A,10(40)A,20(80)A,10(100)A

    Accuracy Class: 1.0,2.0

    Frequency: 50/60Hz

    Impulse Constant: 800imp/kWh,1600imp/kWh,12800imp/kWh

    Display Mode: LCD,Counter

    Power Consumption: 2W,10VA

    Start Current: 0.4%Ib

    Connection Mode: Direct type,CT type

    Creep: Its output is less than one impulse when the voltage

    is 115% voltage rating,the circuit doesn't has any current.

    Standard: IEC62052-11,IEC62053-21

    DIN EN 50022,DIN43880


  • Three-phase DIN-Rail electronic energy meter Five module


    Model: LCD E020CL CT type

    Rated Voltage: 3X220/380V,3X230/400V

    Rated Current: 1.5(6)A

    Accuracy Class: 1.0

    Frequency: 50/60Hz

    Impulse Constant: 12000imp/kWh

    Display: LCD 6+2/7+1/8+0

    Power Consumption: 1W7VA

    Start Current: 0.4%Ib

    Connection Mode: CT type, CT ratio

    Display Digits 6+2: 5/5,10/5,20/5,25/5,40/5,50/5,60/5

    7+1: 75/5,80/5,100/5,120/5,150/5,200/5,250/5,300/5,400/5,500/5,600/5

    8+0: 800/5,1000/5,1200/5,1500/5,2000/5,2500/5,3000/5,4000/5,5000/5,6000/5

    Standard: IEC62052-11,IEC62053-21

    DIN EN 50022,DIN43880


  • Three-phase DIN-Rail electronic energy meter Four module


    Model: LCD D0300L direct type

    LCD D030CL CT type

    Rated Voltage: 3X220/380V,3X230/400V

    Rated Current: 1.5(6)A,5(60)A,5(80)A,10(40)A

    Accuracy Class: 1.0

    Frequency: 50/60Hz

    Impulse Constant: 800imp/kWh,12000imp/kWh

    Display: LCD

    Power Consumption: ≤ 0.6W,0.3VA

    Start Current: 0 .4%Ib

    Connection Mode: D irect type,CT type (the CT ratio could be set by consumer)

    Standard: I E C62052-11,IEC62053-21

    D IN EN 50022,DIN 43880


  • ELECTRO-MAGNETIC COUNTER



    Download
  • Current Transformer



    Download
  • Multimeter and Clamp Meter



    Download
  • Temperature Controllers



    Download
  • Inverter V Series